INPUT | : | 240v±10% 1 phase ac 50Hz |
| | |
OUTPUT | : | VOLTAGE OUTPUT : 0-60KV DC |
| | CURRENT OUTPUT : 2.5mA |
| | RIPPLE : <0.1%P-P |
| | |
VOLTAGE REGULATION | : | Better than 0.05% |
| | |
DESIGN | : | Transformer-less Transistorised Design the unit can be configured for remote operation also |
| | |
CONTROLS | : | Local control with potentio-meters as well |
| | |
LOCAL CONTROL | : | Output voltage, Over voltage setting |
| | Output current trip, Max Current setting |
| | |
REMOTE CONTROL | : | Available |
| | TX-1 connector to be configured as per Instruction manual to achieve remote control |
| | |
TEST AREA INTERLOCK | : | Provided |
| | |
OUTPUT CABLE | : | The set is provided with extremely flexible high voltage cable which has a Copper mesh screen for safety considerations |
| | |
DISPLAY PARAMETERS | : | 3½ Digits voltage & current meters 1.0% accuracy other message indications |
| | OT Over temperature |
| | ID Interlock |
| | EXT REMOTE CONTROL |
| | |
PROTECTIONS | : | Over voltage protection |
| | Over current protection |
| | Protection against output short-circuit and arc discharge |
| | Over temperature protection |